• Cuvette with temperature sensor "in cell".

  • Cuvette, extras C1028.

  • Diehm, Disturbing buffle without NS, length 500 mm. complete clamping NS 29. Material PTFE/PVDF. Above dia 22 mm, below dia 18 mm, offset axes, axis distance. about 30 mm. NS tube connection NS 29/32 for tubes Ø 22 mm. Special clamping system for effective clamping.

  • Installed length 500 mm. With offset axes, usable as disturbing tube. Pt 100 Sensor, class EN 60751 1/3B length: 500 mm. With 3 m cable and Lemo plug (4 wire).

  • Dissolution timer for DRT.

  • Dose Station Ellipta ®

    This is our dedicated delivered dose uniformity test station for Ellipta ®, using the brilliant impinger filter dose collector. The latter is washable in-situ and can be ready for the next dose as part of the wet chemistry work-up procedure. The user works with the equipment in a fixed process which starts by the user placing the device in a nest which mates with the dose collector inlet. Thereafter aided by the station with functions such as dose actuation, solvent delivery, sample agitation and after which the user collects the sample manually. The process is ended with an automated drying procedure. The integration with FIA’s TriggerBox III gives the user full control of the flow process and relevant data recorded on file or printer. Ellipta ® is one of the devices on this product category, see also Turbuhaler ® implementation , but can be made for essentially all devices upon customer request. See also attached flyer for more information for in-depth information.

  • Dose Station Turbuhaler ®

    This is our dedicated delivered dose uniformity test station for Turbuhaler ®, using the brilliant impinger filter dose collector. The latter is washable in-situ and can be ready for the next dose as part of the wet chemistry work-up procedure. The user works with the equipment in a fixed process which starts by the user placing the device in an inlet which mates with the dose collector. The inlet is a highly sophisticated construction with an inflatable gasket which seals around the mouthpiece. Above the gasket there are channels which efficiently rinses the gasket and the filter with solvent. The user is aided by the station with functions such as dose actuation, solvent delivery, sample agitation and dose collector cleaning, after which the user collects the sample manually. The process is ended with an automated drying procedure. The integration with FIA’s TriggerBox III gives the user full control of the flow process and relevant data recorded on file or printer. Turbuhaler ® is one of the devices on this product category, see also Ellipta ® implementation, but can be made for essentially all devices upon customer request. See also attached flyer for in-depth information.

  • DRT2-6 Power cut-off unit.

  • For use with our continuous infusion system or dual infusion systems.
    Provides dual check valves for two syringes, withdraw will pull fluid from a reservoir and infusion will output into a separate line.
    The kit is pre-assembled - just attach the syringes.
    Each dual check valve uses 15 cm. of 1/8" ID tubing connected to a Y connector, one for reservoir and one for output; each Y-connector has 1,5 m. of tubing to make connections to your application. Two 50 mL NormJect Syringes are included.
  • Dynamometric wrench variable 1 - 5 Nm.

  • Electrically Operated Dispenser ED Range

    Dispensers with selected volume of 5 ml, 10 ml, 25 ml, 50 ml, 100 ml or customized volumes. To be integrated and controlled on other equipment. Enquire for more information.
    Please specify specific volume in the additional message bar on checkout

  • Volumetric dispenser with a programmable volume in the interval of 10 to 1100 ml. The volume may be repeated to pump several liters in portions. This function may be used for instance to repeatedly fill vessels.

    On the picture is shown a product version with a stand. It may also be mounted on a stainless lab trolley or with the lower part under a table.

    All parts in liquid contact are corrosion resistant, allowing handling of aggressive liquids and solvents. It is also available for dilution purposes with extra valves.

    Easy to operate via touch panel. No PC is needed. Just type in the desired volume in ml and the dispenser will withdraw the volume from the container and dispense it from the outlet.

    Different liquids will need different withdrawal and infusion (dispensing) speeds which is easily changed through the panel.

    Exact dosage of liquid volumes is in the range of < 10 – 1100 ml. The set volume can be repeated, thus it is also possible to dispense for instance 999 x 1100 ml.

    Standard deviation less than 0.02.

    Volume accuracy and precision: fault < 0.5 ml in the interval 30 – 300 ml and in the interval 300 – 1100 ml < 0.4%.

    The concept can be made in other configurations, such as compact models with shorter but broader cylinders, when a slighty less accurate delivery is acceptable. Lower volume ranges, e.g., 500 ml are also available.

  • Emergency Stop Switch.

  • Power supply and secondary cable only. For use when networking two or more OEM syringe pumps to a single computer serial port. Must use OEM-NET for each additional OEM pump.
  • Allows user to interactively communicate to the pump with a computer using RS-232.
    Includes: power supply, Pump-to-PC network cable (CBL-PC-PUMP-7) and user manual.
  • FIA custom OEM 4501 Dual Channel Syringe Pump with Stall Detection,plastic casing, battery powered, simple operation. Stand alone, suitable for field work, designed and programmed to customer specification.

  • We offer most of the common diameters used for inhaler testing in glass fibre quality from renowned Ahlstrom-Munktell.

  • Duran, 2 necked 100 ml round bottom reaktion vessels, NS 19 center, NS 14 side neck, 10 pcs/cart.

  • Duran, 2 necked 25 ml round bottom reaktion vessels, NS 19 center, NS 14 side neck, 10 pcs/cart.

  • Duran, 2 necked 50 ml round bottom reaktion vessels, NS 19 center, NS 14 side neck, 10 pcs/cart.

Title

Go to Top