The DRT2-6 Power cut-off unit is an electronic part for control of the electronic control devices and the two pneumatical safety valves on FIA Chewing Apparatus DRT2, DRT3 and DRT6.
-
For use with our continuous infusion system or dual infusion systems.
Provides dual check valves for two syringes, withdraw will pull fluid from a reservoir and infusion will output into a separate line.
The kit is pre-assembled - just attach the syringes.
Each dual check valve uses 15 cm. of 1/8" ID tubing connected to a Y connector, one for reservoir and one for output; each Y-connector has 1,5 m. of tubing to make connections to your application. Two 50 mL NormJect Syringes are included. -
ED Immersion Thermostat is a temperature control unit that ideally can be used for temperature control tasks within an internal bath up to 50 L. Temperatures can be easily read via the LED-display screen. An easy keypad (set point, arrow up and arrow down key) is used to enter a set point. The high-performance heating technology, gives a very short heating time. A powerful suction-pressure pump enables ideal circulation with external closed applications.
-
Volumetric dispenser with a programmable volume in the interval of 10 to 1100 ml. The volume may be repeated to pump several liters in portions. This function may be used for instance to repeatedly fill vessels.
On the picture is shown a product version with a stand. It may also be mounted on a stainless lab trolley or with the lower part under a table.
All parts in liquid contact are corrosion resistant, allowing handling of aggressive liquids and solvents. It is also available for dilution purposes with extra valves.
Easy to operate via touch panel. No PC is needed. Just type in the desired volume in ml and the dispenser will withdraw the volume from the container and dispense it from the outlet.
Different liquids will need different withdrawal and infusion (dispensing) speeds which is easily changed through the panel.
Exact dosage of liquid volumes is in the range of < 10 â 1100 ml. The set volume can be repeated, thus it is also possible to dispense for instance 999 x 1100 ml.
Standard deviation less than 0.02.
Volume accuracy and precision: fault < 0.5 ml in the interval 30 â 300 ml and in the interval 300 â 1100 ml < 0.4%.
The concept can be made in other configurations, such as compact models with shorter but broader cylinders, when a slighty less accurate delivery is acceptable. Lower volume ranges, e.g., 500 ml are also available.
-
With this manifold you can regulate the flow of both vacuum (negative pressure) and pressurised flow while keeping the lab bench tidy. Typically used in combination with mixing inlet (Mixing Inlet - Air-Flow Moderating Inlet (AMI) - AB FIA Online Store) where a precise flow duration might not be needed. For the latter please see our line of critical flow controllers: Flow and Actuation Control - AB FIA Online Store It can come assembled with fittings and tubing and shut-off valves for vacuum and pressurised air. Describe your needs and we will come back with an offer.
-
Automated Delivered Dose uniformity (DDU) and Waste station. A large number of inhalers is loaded into a magazine and the controller works down a list of operations such as delivered dose testing and waste dosing (between periods of the dosing regime). The technology builds on well-established process control equipment from, e.g., Siemens and Festo, why it sits well withing the customers existing support and maintenance organisation. Can be customized to your device. Read more here.
-
Glass Frit Impinger DUSA
Used as an alternative to the DUSA after proper equivalence testing (ask us how!). Used by many of the leading companies within OINDP testing. This filter comes in various forms but adheres to the principles which was published in a USP stimuli article 1993. 1 It lends itself to high-capacity testing and automation since it is washable with good recovery and minor carry-over.
- 1. Hugosson, S., J. Lindberg, T. Lööf, B. Olsson, âProposals for Standardized Testing of Powder Preparations for Inhalationâ, Pharm Forum, Vol 19-3, 5458-66, 1993
-
Assuring Used Impactor Nozzle Quality
The ability to self-manage impactor nozzle quality is an important benefit for FIA customers who already own the FIA TrB III trigger box in combination with a speciality lid. FIA is now offering these measurements to customers who send their impactors -- either NGI or ACI -- to FIA for the same nozzle testing! FIA guarantees impactors sent to us for pressure drop measurement will be at FIAâs lab no more than five days! For the upper stages, we have rated pin gages by which we can measure if the stage nozzles are within specification. Pressure drop and dimensional checks will come with a certificate. In our machine shop we can also repair impactors and individual stages after agreement with the customer. The new FIA service, available to all impactor users, is MUCH FASTER and LESS expensive than optical inspection!! TRY IT NOW; youâll be glad you did!!! For more technical understanding, press this link to the text that explains the link between dP, optical stage mensuration, and nozzle quality. If you are looking for the NGI service click here
-
Assuring Used Impactor Nozzle Quality
The ability to self-manage impactor nozzle quality is an important benefit for FIA customers who already own the FIA TrB III trigger box in combination with a speciality lid. FIA is now offering these measurements to customers who send their impactors -- either NGI or ACI -- to FIA for the same nozzle testing! FIA guarantees impactors sent to us for pressure drop measurement will be at FIAâs lab no more than five days! For the upper stages, we have rated pin gages by which we can measure if the stage nozzles are within specification. Pressure drop and dimensional checks will come with a certificate. In our machine shop we can also repair impactors and individual stages after agreement with the customer. The new FIA service, available to all impactor users, is MUCH FASTER and LESS expensive than optical inspection!! TRY IT NOW; youâll be glad you did!!! For more technical understanding, press this link to the text that explains the link between dP, optical stage mensuration, and nozzle quality. If you are looking for the ACI service click here
-
Induvidually Controlled Dissolution Baths
Dissolution bath with four separate vessels with stirrer motors. The stirrers are controlled individually, in terms of start (CW/CCW), stop and speed adjustment. Speed is adjustable between 20-300rpm and actual speed for each stirrer is presented digitally. The motors rest on hinges for better access when preparing the samples in the vessels. Stirrer shaft diameter is 10mm. Immersion heater is centrally positioned in the common water bath. The bath has ample lightning and it is possible to inspect the vessels underneath.
-
Holds 1 Syringe from micro-liter sizes up to 60 mL. (140 mL partially filled).
Infusion rates from 0.73 uL/hr (1 mL syringe) to 1500 mL/hr (60 mL syringe).
Easy-to-use keypad interface:
Set the syringe diameter, pumping rate, press Start,
Pumps continuously until you stop the pump.
Syringe purge mode:
Power failure mode allows pump to continue pumping after a reset.
Displays total volume dispensed in mL or uL units.
Infusion rate can be changed while pumping.
Selectable infusion rates units: mL/hr, uL/hr, mL/min, uL/min.
Space Saving Chassis: Foot print size of only 5 3/4" x 8 3/4".
Won't take up unnecessary space on your laboratory or production bench.
Remembers previous settings on power up.
Precise reproducible flow rates.
Operates from included 12VDC power supply.
Worldwide power supplies available
Disposable, Glass, Stainless Steel Syringes and Plumbing Supplies are sold separately. Pictured Syringe is for Demonstration purposes only. -
Inhaler mouthpiece adapter IP blue to impactor induction port.
Material: Blue silicone (harder and more durable). FIA also sells impactors and induction ports.