• The Controlled Pump is designed to run 32 different pump programs that are easy selectable by two thumb wheels on the front panel. A program consists of one infusion motion and one withdrawal motion which are both configurable with stroke length and speed.

    Start a selected pump program by press of the green “START/STOP” push button at the front panel. The pump will start infuse with parameters from the selected pump program. When the pump reach the programmed end position, it will immediately withdraw and then infuse and so on, as long as the latched push button is in its inner position.

    Specifications
    Dimensions: 122 x 140 x 350 mm. (WxDxH)
    Weight: 4,4 kg.
    Power supply: External power supply, 24 VDC 2,5 A
    Glass syringe connection for external equipment: Luer Lock
    Maximum infusion/withdrawal volume: 20 ml.
    Maximum infusion/withdrawal rate (measured directly against atmosphere) 50 ml/s.
    Lowest infusion/withdrawal rate (measured directly against atmosphere) 6 ml/s.

  • Cleaning service per pair.

  • The standard FIA Chewing Apparatus DRT has a fixed operation for the masticating jaw´s movements. The linear movements Press and Open are achieved by a pneumatic cylinder that is forced to reach the end positions of the cylinder. In a similar way the twist motion must always reach the end position (Twist). (The positions of the twist cylinder are Twist and Regain, where only Twist is acting on the chewing gum by torque forces). The PTM module enables the ability to register pressure and torque forces during the mastication of chewing gums. There is also the possibility to set a maximum pressure value before the chewing sequence proceed with the twist movement. A PTM module can optionally be added to the apparatus which enable both pressure control with monitoring and torque monitoring. If the maximum value is reached for the pressure on the gum, the twisting movement of the jaws is achieved even if the end position of the Press-movement is not reached. With a hard gum, the gap between the jaws must not necessarily be reached before Twist motion is applied on the gum. The PTM module must be ordered for various amount of chewing cells during purchase of a new Chewing Apparatus. It can’t be retrofitted.

  • The Chewing Apparatus is made to masticate chewing gums, especially medicated chewing gums. DRT-6 is equipped with six chewing cells for masticating of six gums/samples at a time. The apparatus is well established within the industry and academia.

  • The Chewing Apparatus is made to masticate chewing gums, especially medicated chewing gums. DRT-3 is equipped with three chewing cells for masticating of three gums/samples at a time. The apparatus is well established within the industry and academia.

  • The Chewing Apparatus is made to masticate chewing gums, especially medicated chewing gums. DRT-2 is equipped with two chewing cells for masticating of two gums/samples at a time. The apparatus is well established within the industry and academia.

  • The Chewing Apparatus is made to masticate chewing gums, especially medicated chewing gums. DRT-1 is equipped with one chewing cell for masticating of one gum/sample at a time. The apparatus is well established within the industry and academia.

  • Patient Realistic Inhaler Testing

    The F-SIG 6300 by AB FIA is a breathing profile generator that is capable of replaying complex breathing patterns. Thanks to a novel multi-cylinder design F-SIG 6300 enables generation of a number of clinical relevant patterns. F-SIG 6300 is not intended for clinical use on humans. The areas of operation are for instance: Testing of pharmaceutical inhalers and nebulizers with human breathing patterns. Characterization of cigarettes (smokers profiles). Rodent profiles and general respiratory research that includes very controlled breathing patterns.

    User Friendly and Versatile

    The F-SIG 6300 is operator-friendly and comes with a touch panel. Profiles, possibly recorded by FIA's Metivent software, are handled and modified in a spreadsheet (e.g. Excel) and the profile library is downloaded to the F-SIG 6300. The operator can thereafter, from the library of profiles, select desired profile on the panel and start the replay of the profile.

    Application Examples

    The equipment is typically placed on the floor, under the table. Above the table the experiment is set up, as shown here an NGI with mixing inlet to simulate patient realistic profiles when measuring APSD. Alternative control and monitoring equipment is also at display, all available from FIA.

    Equipment:

    F-SIG 6300 consists of a breathing profile generator built into a box with transparent plastic covers and placed on wheels. The control system of the multi-cylinder package is configured and operated by the user through the touch panel. Capacity large volume: 0 - 6.3 liters Capacity small volume: 0 - 0.1 liters Voltage: 95 - 255VAC, 50 - 60Hz, 6.5A Dimensions HxWxD: 380x1036x480 mm, Touch Panel: 80x280x170 mm

    Download the pdf Patient Realistic Inhaler Testing
  • Termostated high base chamber for attaching the cuvette and lower chewing surface on FIA Chewing Apparatus DRT.

  • The axis is the heat insulated part where upper chewing jaw is attached. With this part, the jaw distance is adjusted. One item is required for each cell on FIA Chewing Apparatus DRT.

  • Automatic blasting machine: for jaws.

Go to Top