The DRT2-6 Power cut-off unit is an electronic part for control of the electronic control devices and the two pneumatical safety valves on FIA Chewing Apparatus DRT2, DRT3 and DRT6.
-
For use with our continuous infusion system or dual infusion systems.
Provides dual check valves for two syringes, withdraw will pull fluid from a reservoir and infusion will output into a separate line.
The kit is pre-assembled - just attach the syringes.
Each dual check valve uses 15 cm. of 1/8" ID tubing connected to a Y connector, one for reservoir and one for output; each Y-connector has 1,5 m. of tubing to make connections to your application. Two 50 mL NormJect Syringes are included. -
ED Immersion Thermostat is a temperature control unit that ideally can be used for temperature control tasks within an internal bath up to 50 L. Temperatures can be easily read via the LED-display screen. An easy keypad (set point, arrow up and arrow down key) is used to enter a set point. The high-performance heating technology, gives a very short heating time. A powerful suction-pressure pump enables ideal circulation with external closed applications.
-
Volumetric dispenser with a programmable volume in the interval of 10 to 1100 ml. The volume may be repeated to pump several liters in portions. This function may be used for instance to repeatedly fill vessels.
On the picture is shown a product version with a stand. It may also be mounted on a stainless lab trolley or with the lower part under a table.
All parts in liquid contact are corrosion resistant, allowing handling of aggressive liquids and solvents. It is also available for dilution purposes with extra valves.
Easy to operate via touch panel. No PC is needed. Just type in the desired volume in ml and the dispenser will withdraw the volume from the container and dispense it from the outlet.
Different liquids will need different withdrawal and infusion (dispensing) speeds which is easily changed through the panel.
Exact dosage of liquid volumes is in the range of < 10 – 1100 ml. The set volume can be repeated, thus it is also possible to dispense for instance 999 x 1100 ml.
Standard deviation less than 0.02.
Volume accuracy and precision: fault < 0.5 ml in the interval 30 – 300 ml and in the interval 300 – 1100 ml < 0.4%.
The concept can be made in other configurations, such as compact models with shorter but broader cylinders, when a slighty less accurate delivery is acceptable. Lower volume ranges, e.g., 500 ml are also available.