All Products

  • Software for operating and read out of measured data from data loggers used with DRT1-6 PTM (pressure and torque monitoring) functionality. Needed when more than one chewing cell are equiped with PTM.

  • Waste Station Ellipta

    This is our dedicated waste station for Ellipta. The user puts the Ellipta in a nest and closes a safety cover. The station then automatically mates the inhaler with the mouthpiece adapter, withdraws dose and then reverts. The process is repeated according to a user defined number, with selectable delay-time in between. The doses are collected on a high-capacity filter, with a holding capacity of about 10 g. The disposable filter is then safely and easily replaced. The integration with FIA’s TriggerBox III gives the user full control of the flow process and relevant data recorded on file or printer. Can be equipped with anti-static-device. See here for more information.

  • Waste Collection Station

    Our basic yet efficient and flexible waste collection station. The user loads the dose and inserts the device into a dedicated mouthpiece adapter. The doses are collected on a high-capacity filter, with a holding capacity of about 10 g. The disposable filter is then safely and easily replaced. The integration with FIA’s TriggerBox III gives the user full control of the flow process and relevant data recorded on file or printer. Can be equipped with anti-static-device.

  • Valve terminal 3M (complete unit with fittings and silencer).D139

  • Validation kit for IQ / OQ: Certified calipers, calibrated digital thermometer, digital quartz stopwatch.

  • Tubing 8/12 mm Beige for DRT/meter for cuvettes.

  • Adapter between flowmeter ISO 22 and NGI/ACI induction port.

  • TrB III Trigger Box Delta – All-in-One Flow Controller

    The TrB III Trigger Box ensures compliance with standard pharmacopeial methods, both recording and storing key system parameters, including the actual flow rate and run duration. Many inhaler test methods rely on critical flow conditions across the flow control valve, aiming to ensure the same flow rate on each test. But the TrB III does more – actually measures the flow of each test – so, there are no assumptions.

    A calibrated laminar flow element (LFE) internal to each TrB III enables the user to set the flow rate at the beginning of a test sequence; with this LFE, the TrB III then records the flow rate of each test, ensuring against drift, leaks, and other non-ideal behavior that may introduce variability in test results. The TrB III also records the other more traditional run-time parameters, such as the test duration, the pressure drop across the inhaler device (P1), and the flow control pressure ratio (P3/P2, critical flow if ≤ 0.5). The Delta version can measure pressure drop over, e.g., individual impactor stages to detect blockage, using additional internal sensors.1

    Additional user-friendly functions are leak checking and synchronized device actuation by using the integrated output port. Device actuation enables the flow to start simultaneously with dose actuation of a metered-dose inhaler, allowing a user- defined, fixed flow volume for MDI total dose testing.

    Download AB Fia folder Trigger Box TrB III.

    Key features are:

    • Flow actuation: 0-60 min, 0.1s resolution
    • Actuation counter: Resettable 0-999
    • Foot switch: Yes
    • Display: 7” touch
    • P1 measurement: Yes, 0-16 kPa
    • P3/P2 measurement: Yes
    • Flow measurement: Calibrated 0 – 120 l/min (operating range possibly higher)
    • dP (e.g. stage dP): Yes, high precision 0-6 kPa
    • Automatic leak test: Yes
    • Printable data: Prints new actuations continuously or print all actuations from reset.
      • Date/time of first dose
      •  Instrument ID
      • Instrument ver
      • Flow ”on” time
      • External relay timing
      • Atmospheric pressure
      • Dose number
      • P1 and flow
      • P3/P2 (if < 0.5)
      • dP (stage pressure drop)
    • Relay output for actuation of external equipment: Yes, configurable timing of output relative vacuum opening.
    • Displayed history of recent actuation data: All actuations from reset.
    • Interfaces:
      • Relay output for actuation of external equipment
      • Foot switch actuator
      • USB for CSV export
    • Dimensions (cm): 34x13x13

    Download the pdf TrB III – All in one Flow Controller

  • TrB III Trigger Box – All-in-One Flow Controller

    The TrB III Trigger Box ensures compliance with standard pharmacopeial methods, both recording and storing key system parameters, including the actual flow rate and run duration. Many inhaler test methods rely on critical flow conditions across the flow control valve, aiming to ensure the same flow rate on each test. But the TrB III does more – actually measures the flow of each test – so, there are no assumptions.

    A calibrated laminar flow element (LFE) internal to each TrB III enables the user to set the flow rate at the beginning of a test sequence; with this LFE, the TrB III then records the flow rate of each test, ensuring against drift, leaks, and other non-ideal behavior that may introduce variability in test results. The TrB III also records the other more traditional run-time parameters, such as the test duration, the pressure drop across the inhaler device (P1), and the flow control pressure ratio (P3/P2, critical flow if ≤ 0.5).1

    Additional user-friendly functions are leak checking and synchronized device actuation by using the integrated output port. Device actuation enables the flow to start simultaneously with dose actuation of a metered-dose inhaler, allowing a user- defined, fixed flow volume for MDI total dose testing.

    Download AB Fia folder Trigger Box TrB III.

    Key features are:

    • Flow actuation: 0-60 min, 0.1s resolution
    • Actuation counter: Resettable 0-999
    • Foot switch: Yes
    • Display: 7” touch
    • P1 measurement: Yes, 0-16 kPa
    • P3/P2 measurement: Yes
    • Flow measurement: Calibrated 0 – 120 l/min (operating range possibly higher)
    • Automatic leak test: Yes
    • Printable data: Prints new actuations continuously or print all actuations from reset.
      • Date/time of first dose
      •  Instrument ID
      • Instrument ver
      • Flow ”on” time
      • External relay timing
      • Atmospheric pressure
      • Dose number
      • P1 and flow
      • P3/P2 (if < 0.5)
    • Relay output for actuation of external equipment: Yes, configurable timing of output relative vacuum opening.
    • Displayed history of recent actuation data: All actuations from reset.
    • Interfaces:
      • Relay output for actuation of external equipment
      • Foot switch actuator
      • USB for CSV export
    • Dimensions (cm): 34x13x13

    Download the pdf TrB III – All in one Flow Controller

  • Trigger Box Model II – Critical Flow Controller

    This model builds on the functions of Model I with the addition of differential pressure transducers for measuring and displaying pressure at P1, P2, and P3.

    Key features are:

    • Flow actuation: 0-60 min, 0.1s resolution
    • Actuation counter: Resettable 0-999
    • Foot switch: Yes
    • Display: 4.3” touch
    • P1 Measurement: Yes, 0-16 kPa
    • P3/P2 Measurement: Yes
    • Flow Measurement: No
    • dP (e.g. stage dP): No
    • Printable data: Prints new actuations continuously
      • Flow ”on” time
      • Dose number
      • P1
      • P3/P2 (if < 0.5)
    • Relay output for actuation of external equipment: No
    • Displayed history of recent actuation data: Last 3 actuations
    • USB memory stick export: No
    • Automatic leak test: No
    • Dimensions (cm): 23x13x13
  • Trigger Box Model I – Basic

    This model gives the analyst the basic functionality in a very compact and easily managed format.

    Key features are:

    • Flow actuation: 0-99 min, 0.1s resolution
    • Actuation counter: Resettable, 8 digits
    • Foot switch: Optional
    • Display: 4 and 8 digits
    • P1 Measurement: No
    • P3/P2 Measurement: No
    • Flow Measurement: No
    • dP (e.g. stage dP): No
    • Printable data: No
    • Relay output for actuation of external equipment: No
    • Displayed history of recent actuation data: No
    • USB memory stick export: No
    • Automatic leak test: No
    • Dimensions (cm): 23x13x13

Title

Go to Top